piwik image

Fieldpiece SC460

Fieldpiece SC460 Clamp Meter, 600 VDC, 400 A AC, 1000 uA DC, 50 Mohm, 1.2 in Jaw

Fieldpiece SC460

Fieldpiece Clamp Meter, 600 VDC, 400 A AC, 1000 uA DC, 50 Mohm, 1.2 in Jaw, Counts: 10000, 10 - 400 Hz (Clamp), Backlight Display, TRMS AC Response, 2% +/-10 Accuracy, AC: 1.2%+/-10, DC: 0.5% +/-5 Accuracy, CAT III 600 V Safety Rating, 9V 100 hr Typical Alkaline Battery Power Supply, 32 - 122 deg F at Less Than 70% RH Operating, 10000 uF, 3% +/-5 Accuracy, 1% +/-5 Digit DC Current Accuracy, 1% +/-5 Digit Accuracy, AC: 0.0001 V, 0.01 A, DC: 0.0001 V, 0.1 uA, Resistance: 0.01 ohm, Capacitance: 0.00001 uF, Frequency: 0.1 Hz, Temperature: 0.1 deg F Resolution, +/-1 deg F Accuracy, -58 to 2372 deg F

Voltage Rating      :      600 VDC
Amperage Rating      :      400 A AC, 1000 uA DC
Resistance      :      50 Mohm
Jaw Capacity      :      1.2 in
Counts      :      10000
Frequency Rating      :      10 - 400 Hz (Clamp)
Display Type      :      Backlight
AC Response      :      TRMS
AC Current Accuracy      :      2% +/-10
Voltage Accuracy      :      AC: 1.2%+/-10, DC: 0.5% +/-5
Safety Rating      :      CAT III 600 V
Power Supply      :      9V 100 hr Typical Alkaline Battery
Operating Temperature      :      32 - 122 deg F at Less Than 70% RH
Capacitance      :      10000 uF
Capacitance Accuracy      :      3% +/-5
DC Current Accuracy      :      1% +/-5 Digit
Resistance Accuracy      :      1% +/-5 Digit
Resolution      :      AC: 0.0001 V, 0.01 A, DC: 0.0001 V, 0.1 uA, Resistance: 0.01 ohm, Capacitance: 0.00001 uF, Frequency: 0.1 Hz, Temperature: 0.1 deg F
Temperature Accuracy      :      +/-1 deg F
Temperature Rating      :      -58 to 2372 deg F
  • Job Link mobile system capability via JL2 transmitter: send and save electrical measurements to Job Link mobile system app via the JL2 long range transmitter for professional reporting, plus, calculate power (kW) and system efficiency (EER and SEER) for in D understanding of system performance in real world conditions
  • Electrical testing for HVACR - true RMS readings through the clamp or leads, capture starting amps with Inrush
  • Rugged dual display - broad temperature range tolerance allows for testing in freezers and on rooftops
  • Capacitance - test motor start and run capacitor, determine when a capacitor needs to be replaced
  • Wireless testing send measurements to the Job LinkTM mobile system app via JL2 transmitter or view measurements from other compatible tools (ET2W, EH4W, SC57, LT17AW, SC460, SC660) across the jobsite LIVE
  • Magnetic hanger - hanging strap flips out to keep the meter locked in place
  • Trusted temperature: reliable temperature in fast changing environments
  • Hold/max/min
  • High voltage LED and beeper warning
  • Non contact voltage LED and beeper
  • Continuity LED and beeper
  • Diode test
  • Easy temperature calculations
  • Frequency (Hz) through the clamp
  • Low ohm range for motor windings
  • Auto power-off
  • NIST traceable
  • Test 3-Phase power test - conveniently test phase rotation without carrying around an extra meter or extra lead, with the included alligator test lead connected to L1, you can determine phase rotation with one hand