Heat-Flo offers quality indirect water heating systems that provide abundant hot water, low operating cost and long life. Hot water from any heating boiler is circulated through the coil inside to heat all the water in the tank. Simply add another zone to your existing heating boiler.
Heat-flo Indirect Water Heater, 50 gal Capacity, 133280 Btu/hr BTU, 14 gal/min, 223 gal/hr at 140 deg F, 291 gal/hr at 115 deg F First Hour Delivery, 3/4 in NPT Inlet/Outlet Domestic Water, 1 in NPT Inlet/Outlet Boiler Water Connection, 150 lb/sq-in Working, 90 lb/sq-in Coil Pressure, 8.2 sq-ft Coil Heating Surface, 178 gal/hr at 140 deg F, 246 gal/hr at 115 deg F Continuous Draw, 6 ft Pressure Drop, Stainless Steel, 200 deg F, 54 in H x 23-1/2 in Dia
Capacity | : | 50 gal |
BTU Rating | : | 133280 Btu/hr |
Flow Rate | : | 14 gal/min |
First Hour Delivery | : | 223 gal/hr at 140 deg F, 291 gal/hr at 115 deg F |
Connection Type | : | 3/4 in NPT Inlet/Outlet Domestic Water, 1 in NPT Inlet/Outlet Boiler Water |
Pressure Rating | : | 150 lb/sq-in Working, 90 lb/sq-in Coil |
Coil Heating Surface | : | 8.2 sq-ft |
Continuous Draw | : | 178 gal/hr at 140 deg F, 246 gal/hr at 115 deg F |
Pressure Drop | : | 6 ft |
Material | : | Stainless Steel |
Temperature Rating | : | 200 deg F |
Dimensions | : | 54 in H x 23-1/2 in Dia |