piwik image

Bard® HR35BP-A05EPXXXX

Bard® Fusion-Tec HR35BPA HR35BP-A05EPXXXX Package Air Conditioner With Circu

Bard® HR35BP-A05EPXXXX

Bard® Fusion-Tec Package Air Conditioner with Circuit Breaker, Series: HR, HR35BPA Model, 3 ton Nominal, 35000 Btu/hr Cooling BTU Rating, 208 - 230 VAC, 30 A, 5 kW Electric Heat Strip, 60 Hz, 1 -Phase, Scroll Compressor, R-410A Refrigerant, Wall Mounting, 16 x 25 x 1 in Filter, 35 A Fuse, Baked Enamel, Beige, 36.86 in W x 71.61 in H x 27.33 in D

Series      :      HR
Model      :      HR35BPA
Cooling BTU Rating      :      35000 Btu/hr
Nominal Capacity      :      3 ton
Voltage Rating      :      208 - 230 VAC
Amperage Rating      :      30 A
Refrigerant Type      :      R-410A
Mounting Type      :      Wall
Wattage      :      5 kW Electric Heat Strip
Frequency Rating      :      60 Hz
Phase      :      1
Compressor Type      :      Scroll
Fuse Rating      :      35 A
Finish      :      Baked Enamel
Color      :      Beige
Dimensions      :      36.86 in W x 71.61 in H x 27.33 in D
  • Revision level (B)
  • Programmable logic board control logic and climate
  • Factory installed economizer (all units) vent package
  • MERV 8 disposable pleated filter
  • Copper/aluminum evaporator coil, copper/aluminum condenser coil
  • Standard accessories including air flow sensor, dirty filter sensor, pressure transducers, crankcase heater
  • The Fusion-Tec has been designed specifically to optimize free cooling opportunities
  • Reverse air flow - peak performance low side air discharge directs the cooler air used for electronics and equipment cooling at floor level where it is needed
  • Free cooling unit - all units are designed to optimize any free cooling outdoor air opportunities
  • Logic board - system control panels are equipped with PLC logic boards that allow multiple unit operation with a one-controller
  • Advanced unit diagnostics - whether connected to the Tec-Eye diagnostic tool, or just viewed from the shelter control, the system PLC logic board is able to display stored alarms and easy to read diagnostic information
  • Orphan mode - system is designed to run independently if communication to the LV controller is lost, meaning that cooling can be provided even if the controller or wiring fails
  • Air flow switch: all systems feature an air flow switch to monitor blower operation, settings are field adjustable with alarm signal
  • Dirty filter switch - all systems include an air flow switch to monitor pressure drop across the unit filter
  • High pressure transducer - a high pressure transducer is used for advanced diagnostic features including an alarm signal when condenser coil cleaning is needed
  • Low pressure transducer - a pressure transducer is used for advanced diagnostic features and indication of refrigerant loss
  • Security features - by selecting the BardGuard option, electronic security features allow the system to sense coil and copper theft and features multiple alarm options, an in-shelter disarm button allows authorized personnel to service the system