Honeywell Super Tradeline Ignition Module, 24 VAC, 2 A Maximum Valve, 0.4 A Plus Valve Load Current Draw, 5 A at 120 VAC Contact, 60 Hz, 32 s Pre Purge Time Delay, -40 to 175 deg F, 1-15/16 in L x 4-1/16 in W x 5-1/4 in H
|
Voltage Rating
|
:
|
24 VAC
|
|
Amperage Rating
|
:
|
2 A Maximum Valve, 0.4 A Plus Valve Load Current Draw, 5 A at 120 VAC Contact
|
|
Frequency Rating
|
:
|
60 Hz
|
|
Time Delay
|
:
|
32 s Pre Purge
|
|
Temperature Rating
|
:
|
-40 to 175 deg F
|
|
Dimensions
|
:
|
1-15/16 in L x 4-1/16 in W x 5-1/4 in H
|
- Single rod (local sense) or 2-rod (remote sense) ignition
- 1.5 sec flame failure response time
- 4 or 7 sec lockout timing
- One or three ignition trials to lockout
- Igniter warm up time: 7 (12 sec 2nd and 3rd trial), 17 (27 sec 2nd and 3rd trial), 34 or 45 sec
- Replaces over 800 White Rodgers, Robertshaw and Honeywell hot surface ignition models
-