Aspen Air Handler, Series: LGM Series, Model: LGM24B, 24 ton Nominal Capacity, 18000 to 24000 Btu/hr Cooling, 18000 to 24000 Btu/hr, 120 V, 4.8 A, 1/3 hp Rating, 1030 cfm Rating, Horizontal Configuration, R-410, 15 A Fuse, 12 x 20 in Filter, 2 Stage, ECM Motor, 1 in-WG, Rail Mount, Steel, Galvanized, 40 in H x 14-1/2 in W x 21-1/2 in D, Additional Information: High Efficiency, Aluminum Coil
|
Series
|
:
|
LGM Series
|
|
Model
|
:
|
LGM24B
|
|
BTU Rating
|
:
|
18000 to 24000 Btu/hr
|
|
Cooling Capacity
|
:
|
18000 to 24000 Btu/hr
|
|
Nominal Capacity
|
:
|
24 ton
|
|
HP Rating
|
:
|
1/3 hp
|
|
CFM Rating
|
:
|
1030 cfm
|
|
Voltage Rating
|
:
|
120 V
|
|
Amperage Rating
|
:
|
4.8 A
|
|
Configuration
|
:
|
Horizontal
|
|
Number of Stages
|
:
|
2
|
|
Refrigerant Type
|
:
|
R-410
|
|
Mounting Type
|
:
|
Rail
|
|
Fuse Rating
|
:
|
15 A
|
|
Motor Type
|
:
|
ECM
|
|
Pressure Rating
|
:
|
1 in-WG
|
|
Material
|
:
|
Steel
|
|
Finish
|
:
|
Galvanized
|
|
Dimensions
|
:
|
40 in H x 14-1/2 in W x 21-1/2 in D
|
|
Additional Information
|
:
|
High Efficiency, Aluminum Coil
|
- APPLICATION VERSATILITY - Upflow or horizontal right as shipped (field convertible for downflow or horizontal left applications). Can be AHRI certified with most brands of air conditioners or heat pumps. ETL-listed for use with all major refrigerants when proper metering device is used.
- LOW LEAKAGE CABINET - Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to installation instructions. Sturdy, fully insulated galvanized steel cabinet with knockout for duct return.
- AIR MOVING SYSTEM - Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed with speeds and torques at the factory for optimal performance and reliability. Direct drive blowers circulate air quietly and efficiently. Rail mounted blowers provide easy removal for service and maintenance.
- ELECTRONIC CONTROL BOARD - An electronic board controls the functioning of the system, reducing moving parts. The board provides a blower time delay to maximize heat/cool extraction and offers an integrated fuse for additional protection.
- ALL ALUMINUM COIL - High efficiency rifled aluminum tubes and enhanced aluminum fins provide maximum heat transfer. All coils factory leak tested with two-stage pressure decay and mass spectrometer process, then nitrogen pressurized, and factory-sealed for maximum reliability. Available with either factory-installed orifice or TXV metering device. Field-installable bolt-on TXVs are also available. Access door allows for easy coil cleaning.