The ICM2920 is a form, fit and functional replacement for the furnace control boards shown in the cross reference section of this guide. The ICM2920 is an automated gas ignition control board that monitors the ignition sequence including the inducer, pressure switch, spark ignition, gas valve, flame sense and circulating blower while maintaining complete safety circuit monitoring including the high limit switch, roll out switch and auxiliary limit switch circuits.
ICM™ Integrated Furnace Control Board, 24-230 V, 50/60 Hz, Additional Information: 6.5 in L x 5.15 in W x 3 in D Dimensions
Voltage Rating
|
:
|
24-230 V
|
Frequency Rating
|
:
|
50/60 Hz
|
Additional Information
|
:
|
6.5 in L x 5.15 in W x 3 in D Dimensions
|
- Controls blower motors, gas valve and spark ignitor in sequence
- Powers a cooling compressor and protects against short cycling
- Selectable heat blower off-delay time
- Control can be used for two-stage cooling by removing a tab
- Flash codes from the onboard LED indicate specific problems for easier troubleshooting
- Repeated ignition failures or flame losses will disable heat operation for safety
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/ICM_ICM2920_Catalog.pdf
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/ICM_ICM2920_Instruction_Installation_Manual.pdf
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/ICM_ICM2920_Catalog.pdf
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/ICM_ICM2920_Instruction_Installation_Manual.pdf