Goodman® Heat Pump, Model: GSZC7, 208/230 V, 24.1 A, 1/3 hp, 60 Hz, 1 ph Phase, 36000 Btu/hr, 16.6 to 17.5 SEER, 8.2 HSPF, C Connection, Scroll Compressor, R-410A Refrigerant, 3/8 in Liquid Line, 7/8 in Suction Line, 40 A Fuse Rating, Tonnage: 3 ton, 75 dBA Sound Level, 2 Stages, Steel, Finish: Powder-Painted, Gray, 65 to 115 deg F, 35-3/4 in H x 35-1/2 in W x 35-1/2 in D, Additional Information: TXV Expansion Device
Model
:
GSZC7
SEER Rating
:
16.6 to 17.5
BTU Rating
:
36000 Btu/hr
Tonnage
:
3 ton
Voltage Rating
:
208/230 V
Amperage Rating
:
24.1 A
Sound Level
:
75 dBA
Refrigerant Type
:
R-410A
HSPF Rating
:
8.2
HP Rating
:
1/3 hp
Frequency Rating
:
60 Hz
Phase
:
1 ph
Compressor Type
:
Scroll
Number of Stages
:
2
Liquid Line Size
:
3/8 in
Suction Line Size
:
7/8 in
Connection Type
:
C
Fuse Rating
:
40 A
Temperature Rating
:
65 to 115 deg F
Material
:
Steel
Finish
:
Powder-Painted
Color
:
Gray
Dimensions
:
35-3/4 in H x 35-1/2 in W x 35-1/2 in D
Additional Information
:
TXV Expansion Device
The two-stage scroll compressor runs at either 65% or 100% capacity, depending on cooling/heating demand, this operational flexibility provides a great energy efficient option when compared to a traditional, single-stage unit
The top performance of an electronically commutated motor (ECM) allows for two levels of operation depending on your airflow needs, it is a great energy efficient option when compared to a traditional, single-speed motor
Designed to regulate and communicate with your ComfortBridge™ controls system so you can remotely monitor and manage your heating and cooling system at any time, from anywhere with just an internet connection
Filter driers play a pivotal role in the operation of air conditioning and refrigeration systems, a factory installed filter drier absorbs and filter's residual system contaminants and moisture
Ensures refrigerant is ready even in extreme external temperatures
Prevents condensation of refrigerant in the crankcase of a compressor
Reduces pass-through vibration noise from compressor operation
A high pressure switch prevents the system from operating at extremely high pressures by shutting off the compressor circuit if the pressure exceeds the designated rating, when a refrigeration system operates at lower than normal pressures, the low pressure switch prevents freezing from working its way to the compressor
High density foam compressor blanket provides noise reduction when the compressor is in operation
Consistent and concise monitoring helps to ensure that the system is operating efficiently, regardless of the weather
Assists contractors in troubleshooting the system with improved diagnostic accuracy by utilizing indicator lights, seven segment LED display and fault code storage
Time delay defrost technology allows for a reliable, quiet and smooth transition when units enter defrost mode
By simplifying the communication connection to two low voltage wires to the outdoor unit, technicians may eliminate the need to run additional thermostat wiring
Contractors can securely connect wires with large screw lugs, allowing for quick and solid wiring
Proprietary, self-contained sequence of actions designed to help control system operation for energy efficient performance and enhanced reliability
Fully charged with refrigerant sufficient for 15 ft of tubing length to assist with easy installation of unit
A straight forward, color-coded terminal strip for non-communicating set-up helps to simplify installation
Copper coil tubing with enhanced aluminum fins increases the area for heat absorption, providing outstanding, energy efficient heat transfer performance