The Q340A thermocouples sense the pilot flame on standing pilot gas-fired heating systems. The pilot flame heats the tip of the thermocouple, producing a temperature differential between it and the base to generate 30 millivolts.
Honeywell Home Universal Thermocouple, 30 mV, 0.02 Ohm Resistance, 11/32 in Connection, 30 in Wire Lead Length, 760 deg C Hot, 416 deg C Cold Operating Temperature, Additional Information: Male Nut Connector
Voltage Rating | : | 30 mV |
Resistance | : | 0.02 Ohm |
Connection Size | : | 11/32 in |
Wire Lead Length | : | 30 in |
Operating Temperature | : | 760 deg C Hot, 416 deg C Cold |
Additional Information | : | Male Nut Connector |