piwik image

Goodman® GLXS4MA1810

Goodman® GLXS4M GLXS4MA1810 Split-System Air Conditioner, 208/230 V

Goodman® GLXS4MA1810

Goodman® Split-System Air Conditioner, Model: GLXS4M, 1.5 ton Nominal Capacity, 18000 Btu/hr Cooling Capacity, 208/230 V, 11.1 A, 1520 W Wattage, 1/8 hp, 60 Hz, 1 ph Phase, Scroll Compressor, 525 cfm, Up to 15.2 SEER, R-32 Refrigerant, 3/8 in Liquid Line, 3/4 in Suction Line, 73 dBA Sound Level, Sweat Connection, 15 A Fuse Rating, PSC Motor, 75 to 115 deg F, Steel, Finish: Galvanized/Powder-Painted, Gray, 27 in H x 26 in W x 26 in D, Additional Information: Energy-Efficient

Model      :      GLXS4M
SEER Rating      :      Up to 15.2
Cooling Capacity      :      18000 Btu/hr
HP Rating      :      1/8 hp
Nominal Capacity      :      1.5 ton
Compressor Type      :      Scroll
Voltage Rating      :      208/230 V
Amperage Rating      :      11.1 A
Wattage      :      1520 W
Frequency Rating      :      60 Hz
Phase      :      1 ph
CFM Rating      :      525 cfm
Refrigerant Type      :      R-32
Liquid Line Size      :      3/8 in
Suction Line Size      :      3/4 in
Sound Level      :      73 dBA
Connection Type      :      Sweat
Fuse Rating      :      15 A
Motor Type      :      PSC
Temperature Rating      :      75 to 115 deg F
Material      :      Steel
Finish      :      Galvanized/Powder-Painted
Color      :      Gray
Dimensions      :      27 in H x 26 in W x 26 in D
Additional Information      :      Energy-Efficient
  • High-Efficiency Scroll Compressor
  • Factory-installed filter drier
  • Fully charged for 15' of tubing length
  • 5mm diameter copper tube/enhanced aluminum fin coil
  • Service valves with sweat connections and easy-to-access gauge ports
  • Energy-efficient compressors are designed to efficiently deliver indoor comfort, possibly saving on monthly energy costs.
  • A single-speed permanent split capacitor (PSC) condenser fan motor is designed to provide consistent airflow for optimum system performance.
  • Filter-driers play a pivotal role in the operation of air conditioning and refrigeration systems. A factory installed filter-drier absorbs and filter''s residual system contaminants and moisture.
  • Fully charged with refrigerant sufficient for 15' of tubing length to assist with easy installation of unit.
  • Contractors can securely connect wires with large screw lugs, allowing for quick and solid wiring.
  • Meets the performance requirements for AHRI certification and complies with ETL North American safety standards.
  • Contractors can easily and securely connect the ground wire with a screw lug.
  • Copper coil tubing with enhanced aluminum fins increases the area for heat absorption, providing outstanding, energy-efficient heat transfer performance.